<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">WES</journal-id><journal-title-group>
    <journal-title>Wind Energy Science</journal-title>
    <abbrev-journal-title abbrev-type="publisher">WES</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Wind Energ. Sci.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">2366-7451</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/wes-10-1625-2025</article-id><title-group><article-title>State-of-the-art efficiency determination of a wind turbine drivetrain on a nacelle test bench</article-title><alt-title>Efficiency determination of wind turbine drivetrain</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Zhang</surname><given-names>Hongkun</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-5172-4867</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Weidinger</surname><given-names>Paula</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff3">
          <name><surname>Mester</surname><given-names>Christian</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Song</surname><given-names>Zihang</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Heller</surname><given-names>Marcel</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Dubowik</surname><given-names>Alexander</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6267-6418</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Tegtmeier</surname><given-names>Bernd</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Eustorgi</surname><given-names>Karin</given-names></name>
          <email>karin.eustorgi@iwes.fraunhofer.de</email>
        </contrib>
        <aff id="aff1"><label>1</label><institution>Fraunhofer Institute for Wind Energy Systems IWES, 27572 Bremerhaven, Germany</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Physikalisch-Technische Bundesanstalt, 38116 Braunschweig, Germany</institution>
        </aff>
        <aff id="aff3"><label>3</label><institution>Federal Institute of Metrology METAS, 3003 Bern-Wabern, Switzerland</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Karin Eustorgi (karin.eustorgi@iwes.fraunhofer.de)</corresp></author-notes><pub-date><day>14</day><month>August</month><year>2025</year></pub-date>
      
      <volume>10</volume>
      <issue>8</issue>
      <fpage>1625</fpage><lpage>1636</lpage>
      <history>
        <date date-type="received"><day>14</day><month>June</month><year>2024</year></date>
           <date date-type="rev-request"><day>30</day><month>July</month><year>2024</year></date>
           <date date-type="rev-recd"><day>27</day><month>March</month><year>2025</year></date>
           <date date-type="accepted"><day>6</day><month>May</month><year>2025</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2025 Hongkun Zhang et al.</copyright-statement>
        <copyright-year>2025</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025.html">This article is available from https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025.html</self-uri><self-uri xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025.pdf">The full text article is available as a PDF file from https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e157">The efficiency of wind turbine drivetrains is a topic of great interest for both the wind energy industry and the academic community. With the developing maturity of this technology and the increasing pressures to reduce costs, the importance of drivetrain efficiency has grown. However, measuring the mechanical input power and the electrical output power with sufficient accuracy is very challenging due to the high power level of the drivetrain. In the project known as WindEFCY, state-of-the-art measurement and calibration instruments are used to determine the drivetrain efficiency of a direct drive wind turbine on the nacelle test bench called DyNaLab. This paper discusses the test configuration applied for this work as well as the instrumentation of the measurement systems used. It further presents the results from two tests of different types to demonstrate the process of efficiency determination, the analysis of uncertainty and the consequent comparability of the tests. Within the paper's scope of study, an uncertainty level of approximately 0.7 % is achievable when measuring drivetrain efficiency. Details and recommendations concerning data processing and uncertainty analysis are also given in the paper.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>European Metrology Programme for Innovation and Research</funding-source>
<award-id>19ENG08</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e169">To further reduce the levelised cost of energy (LCOE), increasing the rated power of a single wind turbine is still a common and effective approach that is actively pursued by the wind energy industry. When developing larger wind turbines, it is of key interest to maximise the efficiency of wind energy utilisation. This efficiency, however, is not a single and constant parameter. Wind turbines operate in a wide working range that at most times deviates from the rated power and speed. Moreover, wind turbines are constantly subjected to stochastic wind conditions that directly or indirectly influence efficiency. The efficiency property of a wind turbine therefore has to be determined across the entire working range and under different conditions. The determined efficiency property provides an important basis for turbine optimisation.</p>
      <p id="d2e172">The overall efficiency of the wind turbine consists of the aerodynamic efficiency of the rotor and the efficiency of  the drivetrain. The drivetrain efficiency is affected by a number of factors that have to be considered in the design of the turbine. These factors include the setting and functionality of the cooling system, the structural deformation (especially the air gap change for direct drive turbines) due to external loads and temperature change, as well as control strategies of the generator and converter. In order to validate and optimise the turbine design, the influence of these factors on the drivetrain's efficiency needs to be determined both qualitatively and quantitatively. To do so, it is necessary to determine the efficiency with a high level of accuracy and with measurements traceable to national standards according to metrological rules  <xref ref-type="bibr" rid="bib1.bibx9" id="paren.1"/>. Traceability to national standards and the accuracy and precision defined by the calibration, which is a comparison of the measurements on hand with national standards, are of great importance for optimising efficiency. A performance comparison of different drivetrain components or working conditions is only meaningful if the measurement methods and conditions are sufficiently accurate to be able to compare the measurement results with each other.</p>
      <p id="d2e178">The best place to determine the drivetrain efficiency of a wind turbine is on a nacelle test bench, where the design mechanical load cases and electrical grid conditions can be easily produced and replicated. This said, determining efficiency with sufficient accuracy is still very challenging even on nacelle test benches. Major reasons for this are the lack of traceability to national standards in both the mechanical and the electrical fields. Metrological traceability is defined as the “property of a measurement result whereby the result can be related to a reference through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty” <xref ref-type="bibr" rid="bib1.bibx3" id="paren.2"/>. It ensures the accuracy of a measurement described with the measurement uncertainty that is given by the calibration chain. On nacelle test benches, calibration of the torque measurement is especially challenging due to the high torque levels and the absence of torque standards above 1.1 MN <inline-formula><mml:math id="M1" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m <xref ref-type="bibr" rid="bib1.bibx1" id="paren.3"/>. A few approaches have been suggested to avoid the need for torque measurement when determining efficiency on nacelle test benches, including the calorimeter method  <xref ref-type="bibr" rid="bib1.bibx5" id="paren.4"/> and the modified back-to-back method <xref ref-type="bibr" rid="bib1.bibx12" id="paren.5"/>. Nevertheless, the most reliably reproducible method of efficiency determination that is traceable to national standards is still the “direct” method, i.e. measuring the input and output power directly using state-of-the-art equipment. In this case, a 5 MN <inline-formula><mml:math id="M2" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m torque transducer including a device for rotational speed measurement owned by Physikalisch-Technische Bundesanstalt (PTB, the German National Metrology Institute) <xref ref-type="bibr" rid="bib1.bibx8" id="paren.6"/> was used to trace the mechanical power measurement. Additionally, a reference power measuring system (RPMS) calibrated by the Swiss National Metrology Institute METAS together with the PTB was used to trace the electrical power measurement to national standards.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Background</title>
      <p id="d2e219">The WindEFCY project provided the opportunity to determine the efficiency of a wind turbine drivetrain with traceable measurements of both the mechanical input power and the electrical output power. The wind turbine drivetrain was tested on the 10 MW DyNaLab nacelle test bench of Fraunhofer IWES in Bremerhaven, Germany. During the test campaign, the 5 MN <inline-formula><mml:math id="M3" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m torque transducer (also known as the torque transfer standard, TTS) and other mechanical and electrical sensors were used to produce traceable measurements of the input and output powers. The TTS is linked to a primary national torque standard via calibration and transfers the highly accurate and precise torque measurement into industrial applications; here it serves as a reference standard to ensure the accuracy and traceability in torque measurement of the test bench's own torque transducer.</p>
      <p id="d2e229">The WindEFCY project, officially titled “Traceable mechanical and electrical power measurement for efficiency determination of wind turbines”, was a collaborative research initiative across disciplines, such as mechanical and electrical power measurement and wind turbine test bench operation, under the European Metrology Programme for Innovation and Research (EMPIR). The aim of the project was the development and validation of standardised test methods for the efficiency determination of wind turbine drivetrains and their components on test benches in a reliable, reproducible and comparable way for quality assurance. This required several calibration processes and adequate standards. In a calibration process, the unknown measuring instrument is compared with a known standard provided by national metrology institutes, and the accuracy of the unknown measuring instrument is specified within certain tolerances, the measurement uncertainty (MU). Without traceability of the measurands, the accuracy and precision of the measurands are neither known nor reliable. Consequently, the measured quantities cannot be compared with information in data sheets or measurement data acquired by other measuring equipment or in other test benches. To optimise the efficiency of wind turbine drivetrains, where already a good efficiency is achieved, measurements with high accuracy and precision are essential. Within the WindEFCY project, it was shown that – especially in the field of torque measurement in the mega-newton metre range – traceability is obligatory, as the torque measurement discrepancy in test benches was <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">5</mml:mn></mml:mrow></mml:math></inline-formula> %. For discrepancies of this magnitude, it is important that the calibration not only determines the MU, i.e. the range within which the true value of the measured quantity is likely to lie, but also an adjustment to the torque measurement is made to align it with the standard.</p>
      <p id="d2e242">The efficiency behaviour of the turbine drivetrain was determined on numerous working points at 5 MN <inline-formula><mml:math id="M5" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m and under different conditions. In addition to aiding the efficiency determination, the availability of the 5 MN <inline-formula><mml:math id="M6" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS also offered a chance to calibrate the test bench's own torque transducer, which is instrumented on the shaft adapter connecting the test bench and the device under test (DUT), as shown in Fig. <xref ref-type="fig" rid="F1"/>. For the calibration, a number of calibration profiles were also carried out during the test campaign. Since the 5 MN <inline-formula><mml:math id="M7" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS is not designed for high levels of non-torque loads (also known as parasitic loads in some publications), the calibrated test bench transducer could be used instead in future tests with high non-torque loads.</p>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Test layout for efficiency determination</title>
      <p id="d2e276">The layout of the complete test setup is depicted schematically in Fig. <xref ref-type="fig" rid="F1"/>. Two motors of the test bench are connected in tandem to provide the driving torque. A load application unit (LAU) can be used to generate the designed non-torque loads with a hexapod driven by hydraulics. A coupling is placed between the LAU and the motors to prevent non-torque loads being transferred backwards to the motors. The non-torque loads are transferred via a main bearing from the hexapod to the output shaft that also carries the torque. A combination of loads in 6 degrees of freedom can be applied to the DUT through the flange of the output shaft. To connect the test bench with the DUT, a shaft adapter is used to fit the flanges on both sides. This adapter (yellow in Fig. <xref ref-type="fig" rid="F1"/>) is also used as a robust way to measure loads, i.e. torque, bending moments, and axial and lateral forces, directly in front of the DUT. For the WindEFCY test campaign, the 5 MN <inline-formula><mml:math id="M8" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS from PTB (red in Fig. <xref ref-type="fig" rid="F1"/>) was additionally integrated into the setup between the shaft adapter and the DUT with the help of specially designed adaptation structures. To protect the 5 MN <inline-formula><mml:math id="M9" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS, the applied non-torque load was controlled to the minimum during the tests.</p>
      <p id="d2e299">The non-rotating part of the DUT is fixed to the base of the test bench. The DUT's generator is electrically connected to a full power converter, which is in turn connected to the transformer. Via a switch gear, the transformer is connected to the medium voltage inside a junction box. For efficiency determination, the mechanical power is measured by the 5 MN <inline-formula><mml:math id="M10" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS, and the electrical power is measured by the electrical power measurement system (EPMS) in the junction box. The efficiency is then determined for all the components in between, including the generator, the converter and the transformer.</p>

      <fig id="F1" specific-use="star"><label>Figure 1</label><caption><p id="d2e311">Layout of the test configuration with the test bench on the left, the DUT in the middle and the junction box to the grid on the right. The mechanical power is measured between test bench and the DUT with the 5 MN <inline-formula><mml:math id="M11" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS together with a inclinometer. The electrical power is measured in the junction box.</p></caption>
        <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f01.png"/>

      </fig>

</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Measurement of mechanical input power</title>
      <p id="d2e335">The mechanical input power <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">mech</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of the DUT is a function of the input torque <inline-formula><mml:math id="M13" display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> and the rotational speed <inline-formula><mml:math id="M14" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> at the interface of the DUT, as shown in Eq. (<xref ref-type="disp-formula" rid="Ch1.E1"/>). It is very important that the torque and rotational speed being measured at the same position as the power is calculated from both of them. To this end, the 5 MN <inline-formula><mml:math id="M15" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS was augmented by an inclinometer to measure rotational speed. In this chapter, important details of both the torque and the speed measurement are presented.

          <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M16" display="block"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">mech</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mi>M</mml:mi><mml:mo>⋅</mml:mo><mml:mi>n</mml:mi></mml:mrow></mml:math></disp-formula></p>

      <fig id="F2" specific-use="star"><label>Figure 2</label><caption><p id="d2e393">The 5 MN <inline-formula><mml:math id="M17" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS manufactured by HBM (left image). It is a hollow-shaft transducer with flanges to be mounted in test benches. In the left image, the hollow shaft is covered by a cover plate. On the inside of this cover and placed centred is the inclinometer stack (zoom in right image). Moreover, a small sensor to log temperature and humidity inside the TTS is taped to the inner side of the cover plate (right image, black tape). Taken from <xref ref-type="bibr" rid="bib1.bibx6" id="text.7"/>.</p></caption>
        <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f02.jpg"/>

      </fig>

<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Torque measurement with the 5 MN <inline-formula><mml:math id="M18" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS</title>
      <p id="d2e427">To meet the needs of the wind energy industry, a 5 MN <inline-formula><mml:math id="M19" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS manufactured by the company Hottinger Baldwin Messtechnik (HBM) was acquired by PTB especially for the use on nacelle test benches. It is pictured in Fig. <xref ref-type="fig" rid="F2"/> (left). The TTS is equipped with strain gauges interconnected in a Wheatstone bridge circuit to measure torque up to 5 MN <inline-formula><mml:math id="M20" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m. Additionally, it can also measure bending moments, axial and shear forces but only to a lower level, and these additional measurements are not traceable to national standards. The TTS is statically calibrated using PTB's 1.1 MN <inline-formula><mml:math id="M21" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m torque standard machine in order to establish a relationship between the transducer's output signal <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">TTS</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (in mV V<sup>−1</sup>) and the applied torque <inline-formula><mml:math id="M24" display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> (in kN <inline-formula><mml:math id="M25" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m). This was done according to the German torque calibration standard DIN 51309 but only up to 1.1 MN <inline-formula><mml:math id="M26" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m due to the lack of suitable torque standard machines.</p>
      <p id="d2e498">DIN 51309 stipulates which parameters must be determined in addition to the calibration result in order to calculate the MU. These include reproducibility <inline-formula><mml:math id="M27" display="inline"><mml:mi>b</mml:mi></mml:math></inline-formula>, repeatability <inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msup><mml:mi>b</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, resolution <inline-formula><mml:math id="M29" display="inline"><mml:mi>r</mml:mi></mml:math></inline-formula>, zero point deviation <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, and regression or display deviation <inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>. Due to the hysteresis behaviour <inline-formula><mml:math id="M32" display="inline"><mml:mi>h</mml:mi></mml:math></inline-formula> of torque transducers in case of load direction changes, two cases are distinguished when evaluating the sensor behaviour. In Case I, only increasing torque is measured and a linear or cubic regression curve through the origin is calculated, which is used for the future signal display. As there is no load change in this case, the hysteresis behaviour does not need to be taken into account in the MU. In Case II, the sequence of the load, whether increasing or decreasing, is not known. Accordingly, a linear regression curve is calculated based on combined calibration data of both increasing and decreasing torque. The hysteresis of the sensor occurring with alternating load contributes to the overall MU.</p>
      <p id="d2e556">With regard to its application on the test bench, where both increasing and decreasing torque can occur, a linear regression curve combined for increasing and decreasing torque was determined for the calibration of the 1.1 MN <inline-formula><mml:math id="M33" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS in accordance with Case II in DIN 51309. Using the sensitivity and the TTS's signal <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">TTS</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, the torque <inline-formula><mml:math id="M35" display="inline"><mml:mi>M</mml:mi></mml:math></inline-formula> can be calculated:

            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M36" display="block"><mml:mrow><mml:mi>M</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3850</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mtext>kN</mml:mtext><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mo>⋅</mml:mo><mml:mtext>m</mml:mtext><mml:mo>⋅</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mrow><mml:mtext>mV</mml:mtext><mml:mspace width="0.125em" linebreak="nobreak"/><mml:msup><mml:mtext>V</mml:mtext><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:mfenced><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup><mml:mo>⋅</mml:mo><mml:msub><mml:mi>S</mml:mi><mml:mi mathvariant="normal">TTS</mml:mi></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Due to the lack of possible calibration devices above 1.1 MN <inline-formula><mml:math id="M37" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m, the behaviour of the TTS up to 5 MN <inline-formula><mml:math id="M38" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m can only be predicted. With a relative linearity deviation of <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:mn mathvariant="normal">0.7</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> at 1.1 MN <inline-formula><mml:math id="M40" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m and a relative hysteresis of <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">6.2</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> in the measurement range up to 1.1 MN <inline-formula><mml:math id="M42" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m, the TTS exhibits exceptionally linear behaviour. The assumption of partial range sensitivity for full range measurements is supported by the stability of the sensitivity in further partial measurement ranges (8 %, 12 % and 16 %) with relative deviations of <inline-formula><mml:math id="M43" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">8</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> noticeably below the overall MU of <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>.</p>
      <p id="d2e740">The use of a partial range sensitivity for a full range measurement was validated using partial and full range measurements on a very well characterised 20 kN <inline-formula><mml:math id="M45" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m torque transfer standard. The relative deviation of the partial range sensitivity from the full range sensitivity was <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">6</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, which was below the smallest possible overall measurement uncertainty for Case I with a cubic regression curve.</p>
      <p id="d2e768">In addition to the sensitivity, the overall MU is the result of a calibration. Therefore, a MU must be specified for the full measurement range of the TTS on top of the predicted sensitivity. The MU is also a prediction, which should be treated carefully as such, and does not replace a real calibration, where this is possible. A weighted extrapolation method <xref ref-type="bibr" rid="bib1.bibx10" id="paren.8"/> was used to predict the overall MU for the full measurement range. The maximum overall MU of the partial range calibration is multiplied by a prediction factor <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> to account for the uncertainty of the extrapolation itself. This factor is the sum of a scaling factor <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the classification criteria of the partial range calibration according to DIN 51309.</p>
      <p id="d2e796">Besides determining the MU, the classification of measuring devices is a way of presenting the accuracy of the calibrated measuring device in a standardised way that can be recognised at a glance. Classification requires a combination of specific criteria to be met. The classification criteria according to DIN 51309 are as follows: relative reproducibility <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>b</mml:mi><mml:mi mathvariant="normal">rel</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, relative repeatability <inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msubsup><mml:mi>b</mml:mi><mml:mi mathvariant="normal">rel</mml:mi><mml:mo>′</mml:mo></mml:msubsup></mml:mrow></mml:math></inline-formula>, relative zero point deviation <inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">rel</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, relative hysteresis <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:msub><mml:mi>h</mml:mi><mml:mi mathvariant="normal">rel</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, and relative regression deviation <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">rel</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, as well as the resolution of the TTS at the smallest calibrated lower range value <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">A</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the relative MU of the torque standard machine <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msub><mml:mi>W</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>.

            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M56" display="block"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>b</mml:mi><mml:mi mathvariant="normal">rel</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msubsup><mml:mi>b</mml:mi><mml:mi mathvariant="normal">rel</mml:mi><mml:mo>′</mml:mo></mml:msubsup><mml:mo>+</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">rel</mml:mi></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>h</mml:mi><mml:mi mathvariant="normal">rel</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mi mathvariant="normal">a</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">rel</mml:mi></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">A</mml:mi></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>W</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:msub><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          The scaling factor <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the ratio of maximum extrapolated torque <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">ex</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> to the maximum calibrated torque <inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and, therefore, weights the uncertainty higher with increasing extrapolation:

            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M60" display="block"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">ex</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Due to the relative MU of the torque standard machine of <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:mn mathvariant="normal">8</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, the class of the TTS is <inline-formula><mml:math id="M62" display="inline"><mml:mn mathvariant="normal">0.5</mml:mn></mml:math></inline-formula>. For the extrapolated range, the corresponding scaling and weighting factors and the extrapolated MU are shown in Table <xref ref-type="table" rid="T1"/>.</p>

<table-wrap id="T1"><label>Table 1</label><caption><p id="d2e1064">Scaling and weighting factor for the 5 MN <inline-formula><mml:math id="M63" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS calibrated in the sub-range up to 1.1 MN <inline-formula><mml:math id="M64" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m and extrapolated relative expanded MU for the range between 1.5 MN <inline-formula><mml:math id="M65" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m and 5 MN <inline-formula><mml:math id="M66" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="4">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry namest="col1" nameend="col4" align="center">Weighted extrapolation approach </oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Steps</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">w</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4">Extrapolated relative</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry colname="col3"/>
         <oasis:entry colname="col4">expanded MU per %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">0</oasis:entry>
         <oasis:entry colname="col2">–</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">1500</oasis:entry>
         <oasis:entry colname="col2">0.11</oasis:entry>
         <oasis:entry colname="col3">3.2</oasis:entry>
         <oasis:entry colname="col4">0.27</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2000</oasis:entry>
         <oasis:entry colname="col2">0.15</oasis:entry>
         <oasis:entry colname="col3">3.7</oasis:entry>
         <oasis:entry colname="col4">0.3</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">2500</oasis:entry>
         <oasis:entry colname="col2">0.19</oasis:entry>
         <oasis:entry colname="col3">4.1</oasis:entry>
         <oasis:entry colname="col4">0.34</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3000</oasis:entry>
         <oasis:entry colname="col2">0.23</oasis:entry>
         <oasis:entry colname="col3">4.6</oasis:entry>
         <oasis:entry colname="col4">0.38</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">3500</oasis:entry>
         <oasis:entry colname="col2">0.26</oasis:entry>
         <oasis:entry colname="col3">5</oasis:entry>
         <oasis:entry colname="col4">0.42</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4000</oasis:entry>
         <oasis:entry colname="col2">0.3</oasis:entry>
         <oasis:entry colname="col3">5.5</oasis:entry>
         <oasis:entry colname="col4">0.45</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">4500</oasis:entry>
         <oasis:entry colname="col2">0.34</oasis:entry>
         <oasis:entry colname="col3">5.9</oasis:entry>
         <oasis:entry colname="col4">0.49</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">5000</oasis:entry>
         <oasis:entry colname="col2">0.38</oasis:entry>
         <oasis:entry colname="col3">6.4</oasis:entry>
         <oasis:entry colname="col4">0.53</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Measurement of rotational speed with the mechanical power transfer standard</title>
      <p id="d2e1311">The first challenge in establishing a transfer standard for measuring rotational speed in nacelle test benches stems from the difficulty of installing the encoder stator in very close proximity to the rotating shaft. This problem is attributed to the towering height of the rotor hub and the absence of rigid structures. To address this, a stator-free method for measuring rotational speed has been developed using a specially chosen inclinometer. This inclinometer, which functions as a microelectromechanical system (MEMS), contains two perpendicular accelerometers that determine inclination relative to gravity. Placed at the centre of the drivetrain, the inclinometer measures the angular position  (<inline-formula><mml:math id="M69" display="inline"><mml:mi mathvariant="italic">ϕ</mml:mi></mml:math></inline-formula>) of the rotating shaft with respect to gravity. The average rotational speed (<inline-formula><mml:math id="M70" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>) is then calculated based on the change in angle (<inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and the elapsed time (<inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula>), with the following formula:

            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M73" display="block"><mml:mrow><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:mrow><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">60</mml:mn><mml:mrow><mml:mn mathvariant="normal">360</mml:mn><mml:mi mathvariant="italic">°</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e1396">The inclinometer's calibration was performed at the length and angle laboratory at PTB and yielded an expanded MU (with coverage factor <inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) of 0.014° under static conditions using a 0.22 Hz Bessel low-pass filter. Utilising its stator-free characteristic, the inclinometer was mounted on the inner side of the TTS cover plate at the centre part, as depicted in Fig. <xref ref-type="fig" rid="F2"/>.</p>
      <p id="d2e1413">The overall MU (<inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) of rotational speed is influenced by uncertainties in angle (<inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and time (<inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) and is determined by the following equation:

            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M78" display="block"><mml:mrow><mml:msubsup><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup><mml:mo>=</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo>∂</mml:mo><mml:mi>n</mml:mi></mml:mrow><mml:mrow><mml:mo>∂</mml:mo><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo>∂</mml:mo><mml:mi>n</mml:mi></mml:mrow><mml:mrow><mml:mo>∂</mml:mo><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced open="(" close=")"><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo>∂</mml:mo><mml:mi>n</mml:mi></mml:mrow><mml:mrow><mml:mo>∂</mml:mo><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e1549">The standard uncertainties in the angle measurement <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the time measurement <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> contribute to the total standard uncertainty <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of the rotational speed measurement:

            <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M82" display="block"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">60</mml:mn><mml:mrow><mml:mn mathvariant="normal">360</mml:mn><mml:mi mathvariant="italic">°</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msqrt><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:msup><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="italic">ϕ</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mfenced close=")" open="("><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub><mml:mo>-</mml:mo><mml:msub><mml:mi mathvariant="italic">ϕ</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:msup><mml:mi>t</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">t</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow></mml:msqrt><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e1669">It is obvious that <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> decreases as the time interval <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mi mathvariant="normal">Δ</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> increases, thereby reducing uncertainty. To ensure synchronised measurements, the rotational speed was always measured over the same interval as the torque measurement.</p>
      <p id="d2e1693">Incorporating additional uncertainties arising from mounting misalignments, eccentricity, dynamic effects and data evaluation processes, the total relative expanded MU for the rotational speed measurement on the nacelle test bench was calculated as 0.02 %. Using the aforementioned inclinometer, which was developed as a transfer standard for rotational speed and integrated with the 5 MN <inline-formula><mml:math id="M85" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS on the nacelle test bench, a traceability chain for mechanical power measurement is established <xref ref-type="bibr" rid="bib1.bibx11" id="paren.9"/>.</p>
</sec>
</sec>
<sec id="Ch1.S5">
  <label>5</label><title>Measurement of electrical output power</title>
      <p id="d2e1716">Efficiency is the ratio of useful electrical output power <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">elec</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> converted from the available mechanical input power. The electrical output power is the sum of the power of all three phases <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, whereas the power per phase <inline-formula><mml:math id="M88" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> is determined as the product of transient current <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:msub><mml:mi>i</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> and voltage <inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>:

              <disp-formula specific-use="gather" content-type="numbered"><mml:math id="M91" display="block"><mml:mtable displaystyle="true"><mml:mlabeledtr id="Ch1.E8"><mml:mtd><mml:mtext>8</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">elec</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">elec</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">phase</mml:mi><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">elec</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">phase</mml:mi><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mi>P</mml:mi><mml:mrow><mml:mi mathvariant="normal">elec</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">phase</mml:mi><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:msub><mml:mo>,</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr><mml:mlabeledtr id="Ch1.E9"><mml:mtd><mml:mtext>9</mml:mtext></mml:mtd><mml:mtd><mml:mrow><mml:mstyle class="stylechange" displaystyle="true"/><mml:msub><mml:mi>P</mml:mi><mml:mtext>elec,phase 1–3</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mi>T</mml:mi></mml:mfrac></mml:mstyle><mml:munderover><mml:mo movablelimits="false">∫</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mi>T</mml:mi></mml:munderover><mml:msub><mml:mi>u</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:msub><mml:mi>i</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:mtd></mml:mlabeledtr></mml:mtable></mml:math></disp-formula></p>
      <p id="d2e1893">Since the electrical output power is intended to be fed to the electricity grid, only the electrical power at grid frequency is useful. Power quality phenomena such as other spectral components are relevant since they influence, for instance, the stability of the grid. These are also studied, but since they are not considered “useful output” for determining efficiency, the uncertainty requirements are much less stringent. The setup of the electrical gauges in the DyNaLab nacelle test bench is shown in simplified form in Fig. <xref ref-type="fig" rid="F3"/>.</p>
      <p id="d2e1898">In nacelle test benches, electrical power is usually measured using an electrical power measurement system (EPMS) integrated into the test bench’s data acquisition (DAQ) system. This system is optimised for convenience and versatility, not for minimum uncertainty. Since it is integrated into the nacelle test bench, sending this system to calibration laboratories is difficult and time-consuming. For this reason, METAS and PTB calibrated a reference power measuring system (RPMS) for use in test benches. This system is used to determine the efficiency and to calibrate the EPMS measurement chain of the test bench on-site.</p>
      <p id="d2e1901">The RPMS is based on commercial off-the-shelf components such as the LMG671 power analyser and the DL 2000ID current sensors (Fig. <xref ref-type="fig" rid="F3"/>). As the planned reference voltage divider HST12-3 could not be used due to the risk of over-voltage and to test hall safety regulations, the more robust HILO voltage dividers were employed instead, and an extensive recalibration of the HILO sensors had to be carried out at PTB. The over-voltage risk stemmed from the fact that the DUT had to be connected to the medium-voltage grid of the local grid operator instead of to the grid simulator of the test bench. This had the disadvantage that in the event of a fault in the medium-voltage grid, high over-voltages could occur due to ground faults or lightning strikes.</p>
      <p id="d2e1907">The power analyser was used for measurements at the primary side of the transformer. The power analysers were calibrated using a modular primary power standard <xref ref-type="bibr" rid="bib1.bibx4" id="paren.10"/>. Depending on the currents and voltages to be measured, transducers can be used to reduce the currents and voltages to levels that can be measured with the power analyser. These reference transducers are calibrated with an uncertainty of 300 <inline-formula><mml:math id="M92" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>V V<sup>−1</sup> and 30 <inline-formula><mml:math id="M94" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>A A<sup>−1</sup> at power frequency.</p>

      <fig id="F3" specific-use="star"><label>Figure 3</label><caption><p id="d2e1955">Schematic setup (left) and picture (right) of the RPMS and the EPMS in the junction box of the DyNaLab nacelle test bench.</p></caption>
        <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f03.jpg"/>

      </fig>

      <p id="d2e1964">Figure <xref ref-type="fig" rid="F3"/> shows the current measurement chain of the EPMS, consisting of current transformers of type DS 2000 ICLA, burden resistors of type HBR1.0, and the HBM data logger GEN4tB with the current measurement card GN8103B, which could be calibrated on-site. The MU for the measurement chain is 0.01 % and is valid for various load cases. A statement about the long-term stability cannot be made here.</p>
      <p id="d2e1969">Due to the over-voltage risk mentioned above, calibration of the HILO sensors on-site was not possible, as the over-voltages could have damaged the voltage reference sensor of the RPMS. To calibrate the HILO voltage sensors, the entire measurement chain, consisting of voltage divider, connection cable, transmitter, fibre optic cable and receiver (Fig. <xref ref-type="fig" rid="F4"/>), was shipped to and calibrated in the laboratory at PTB following the test campaign. The calibration was performed as a comparison measurement against a PTB standard. Due to a high position dependence of the voltage divider on other voltage dividers, the calibration resulted in an expanded MU (<inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) of 0.8 % at power frequency, with the standard uncertainty being 0.4 %.</p>

      <fig id="F4" specific-use="star"><label>Figure 4</label><caption><p id="d2e1988">Measuring chain of the EPMS voltage path. Source: <uri>https://www.hbm.com/en/2343/isobe5600-isolation-system-standalone-transient-recorder</uri> (last access: 26 July 2024), modified by the authors with permission of Hottinger Brüel &amp; Kjaer GmbH.</p></caption>
        <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f04.png"/>

      </fig>

      <p id="d2e2001">As shown in Table <xref ref-type="table" rid="T2"/>, the uncertainty in the voltage measurement  <inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> plays a dominant role in the overall MU of the electrical power. Thanks to the state-of-the-art sensors and measurement system, the current <inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> can be measured with an extremely small uncertainty. Additionally, since the power factor <inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> of the turbine is kept at <inline-formula><mml:math id="M100" display="inline"><mml:mn mathvariant="normal">1</mml:mn></mml:math></inline-formula> during the test, the uncertainty in <inline-formula><mml:math id="M101" display="inline"><mml:mi mathvariant="italic">λ</mml:mi></mml:math></inline-formula> due to the phase errors of voltage and current sensors is negligible. The uncertainties of the three voltage measurements for the three phases are regarded as independent after the calibration and correction. As a result, the total power of the three phases has a smaller relative uncertainty compared to the power <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mtext>1–3</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> of each individual phase.</p>

<table-wrap id="T2"><label>Table 2</label><caption><p id="d2e2068">Relative MUs for the single components of the electrical power measurement, meaning voltage, current, power factor and electrical power for the three phases, as well as combined relative MU for the overall electrical power.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:colspec colnum="4" colname="col4" align="left"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:msub><mml:mi>I</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">λ</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:msub><mml:mi>P</mml:mi><mml:mi mathvariant="normal">elec</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0.40 %</oasis:entry>
         <oasis:entry colname="col2">0.01 %</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
         <oasis:entry colname="col4">0.40 %</oasis:entry>
         <oasis:entry colname="col5">0.23 %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e2262">For the determination of efficiency, the electrical power and mechanical power measurements need to be synchronised. While the mechanical power measurement system is synchronised to UTC (coordinated universal time) using the IRIG-B signal, the chosen RPMS model cannot be synchronised to an external time reference other than by manually setting the time like on a wristwatch. Mechanical imperfections of the nacelle cause a pattern of mechanical power with a period of one revolution. Since the electrical power shows the same pattern, the electrical power measurement is synchronised in a post-processing stage using the cross correlation of the two power measurements.</p>
</sec>
<sec id="Ch1.S6">
  <label>6</label><title>Test results and analysis</title>
      <p id="d2e2273">During the test campaign, numerous tests serving various purposes were carried out. Because the measurement range of the TTS (being 5 MN <inline-formula><mml:math id="M116" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m) is smaller than the rated torque of the DUT, all tests were carried out with the turbine operating below the rated power. The results of two tests are presented in this paper to demonstrate the method of efficiency determination. In both tests, the torque was held stable around the 5 MN <inline-formula><mml:math id="M117" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m level to utilise the maximum capacity of the transducer. In the first test, the rotational speed was kept constant to be able to analyse the long-term behaviour of the DUT and the temperature influence on the efficiency, while in the second test the rotational speed followed an operational curve in a stepwise manner upwards. For each test, the mechanical input power and the electrical output power were calculated to determine the efficiency. The uncertainty analysis was carried out for the first test with uncertainty budgets of the raw measurements determined according to the propagation principle. The turbine under test was a customer device in development mode. Since the rated rotational speed is a key parameter for a commercial wind turbine, it was agreed to be normalised, which consequently leads to the normalisation of the mechanical and electrical powers in this paper.</p>
<sec id="Ch1.S6.SS1">
  <label>6.1</label><title>Results from warm-up test</title>
      <p id="d2e2297">In the first test, the turbine was operated at a fixed working point for relatively long periods of time, as shown in Fig. <xref ref-type="fig" rid="F5"/>. This is named the warm-up test and is designed to study the change of temperature and hence the drivetrain efficiency over the course of long-term operation.</p>

      <fig id="F5" specific-use="star"><label>Figure 5</label><caption><p id="d2e2304">Actual test progress of the warm-up test: torque (upper part of the figure), measured by PTB's TTS, and rotational speed (lower part of the figure) measured by the rotary encoder of the test bench plotted against time.</p></caption>
          <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f05.png"/>

        </fig>

      <p id="d2e2313">In Fig. <xref ref-type="fig" rid="F6"/> (upper plot), the mechanical and electrical power values are shown in the same plot for better comparison. The efficiency change over the course of operation time is visualised in the lower plot of the same figure. For better comparison, the mechanical and electrical power values are shown in the same figure. The general trend of efficiency drop with progressing operation time can be clearly seen. While the electrical power output is kept constant by means of the control strategy, the mechanical power input increases slowly. Each point in the upper graph represents the mean value of a 10-revolution power measurement; each point in the lower graph represents that of the corresponding efficiency result. The 10-revolution mean values allow better visualisation of the change trend.</p>

      <fig id="F6" specific-use="star"><label>Figure 6</label><caption><p id="d2e2321">Efficiency determination for the warm-up test where both mechanical and electrical powers are depicted in the upper part of the figure, and the efficiency, being calculated as the ratio of electrical output power and mechanical input power, is shown in the lower part of the figure. All variables are plotted as mean data points averaged over 10 revolutions.</p></caption>
          <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f06.png"/>

        </fig>

      <p id="d2e2330">For the reasons listed below, it is difficult, but also not necessary, to measure the instant efficiency at a specific time point. It makes more sense to measure the “mean” efficiency of the drivetrain for 1 or more revolutions.</p>
      <p id="d2e2333"><list list-type="bullet">
            <list-item>

      <p id="d2e2338">The drivetrain has notable inertia and can store and emit energy as the rotational speed fluctuates.</p>
            </list-item>
            <list-item>

      <p id="d2e2344">The torsional vibration of the drivetrain and the speed control strategy cause ripples in the rotational speed and consequently in all other variables measured.</p>
            </list-item>
            <list-item>

      <p id="d2e2350">The performance of the turbine generator, including its efficiency, is dependent on the air gap distribution between the rotor and stator along the circumference, which varies with the angular position of the rotor.</p>
            </list-item>
            <list-item>

      <p id="d2e2356">The electrical power measurement is only carried out once per second. The power analyser can calculate the mean power within each second very accurately, but the power between any two outputs needs to be interpolated.</p>
            </list-item>
          </list></p>
      <p id="d2e2361">The deviation of the determined efficiency based on a one-revolution averaged measurement can be calculated provided sufficient data are available. As an example, Fig. <xref ref-type="fig" rid="F7"/> shows two versions of efficiency determination based on measurement data gathered over 100 revolutions; the upper part of the figure shows results of a 1-revolution average <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, with the standard deviation of the 100 points being 0.13 %. In the lower part of the figure, the efficiency was determined using measurement data being averaged over  10 revolutions, <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, resulting in 10 points in the plot. The standard deviation of these 10 points is 0.019 %.</p>

      <fig id="F7" specific-use="star"><label>Figure 7</label><caption><p id="d2e2390">Standard deviation of 1-revolution and 10-revolution averaged efficiency. The very small drift of efficiency at different revolutions is compensated by a detrend operation in MATLAB.</p></caption>
          <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f07.png"/>

        </fig>

      <p id="d2e2400">The standard deviations of <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>  and <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>  are denoted as <inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M123" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> . A comparison between the two is given in Table <xref ref-type="table" rid="T3"/>. According to the GUM guideline <xref ref-type="bibr" rid="bib1.bibx2" id="paren.11"/>, <inline-formula><mml:math id="M124" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>  would be equal to  <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>  divided by <inline-formula><mml:math id="M126" display="inline"><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:math></inline-formula> if the uncertainties of the determined  <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> values were independent of each other. It should be noted, however, that <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is much smaller than <inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:mrow></mml:math></inline-formula>, as shown in Table <xref ref-type="table" rid="T3"/>.</p>

<table-wrap id="T3"><label>Table 3</label><caption><p id="d2e2551">Comparison of the standard deviations for efficiency <inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M131" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M134" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">0.13 %</oasis:entry>
         <oasis:entry colname="col2">0.04 %</oasis:entry>
         <oasis:entry colname="col3">0.019 %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e2661">This indicates that in this case the determined values of efficiency with single revolution measurement <inline-formula><mml:math id="M135" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> are not independent in terms of MU. Nevertheless, since <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:mrow></mml:math></inline-formula> gives a larger uncertainty than  <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, and  <inline-formula><mml:math id="M138" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> needs a much smaller period of measurement to be calculated than <inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> , it remains meaningful to use <inline-formula><mml:math id="M140" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:mrow></mml:math></inline-formula> as a conservative estimation (Eq. <xref ref-type="disp-formula" rid="Ch1.E10"/>) of <inline-formula><mml:math id="M141" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> if the measurement period or the number of revolutions is limited.

            <disp-formula id="Ch1.E10" content-type="numbered"><label>10</label><mml:math id="M142" display="block"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msubsup><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>/</mml:mo><mml:msqrt><mml:mn mathvariant="normal">10</mml:mn></mml:msqrt></mml:mrow></mml:math></disp-formula></p>
      <p id="d2e2810">The detailed uncertainty budget for the determined efficiency with the averaged measurement of 10 revolutions is shown in Table <xref ref-type="table" rid="T4"/>. The left side of the table presents the uncertainty contributions from the measured electrical and mechanical variables. These are used to determine the efficiency uncertainty associated solely with the measurement chains and denoted as <inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">meas</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. On the right side of the table, the uncertainty associated with the instability in the efficiency is indicated, with the standard deviation adopted as the standard uncertainty <inline-formula><mml:math id="M144" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:mi mathvariant="normal">ins</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>. In this case, the 10-revolution average is used. If the efficiency is determined with the average of a different number of revolutions, the corresponding standard deviation should be used.</p>

<table-wrap id="T4" specific-use="star"><label>Table 4</label><caption><p id="d2e2853">Overall uncertainty budget of the determined drivetrain efficiency.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="5">
     <oasis:colspec colnum="1" colname="col1" align="left" colsep="1"/>
     <oasis:colspec colnum="2" colname="col2" align="left" colsep="1"/>
     <oasis:colspec colnum="3" colname="col3" align="left" colsep="1"/>
     <oasis:colspec colnum="4" colname="col4" align="left" colsep="1"/>
     <oasis:colspec colnum="5" colname="col5" align="left"/>
     <oasis:thead>
       <oasis:row>

         <oasis:entry colname="col1">Current</oasis:entry>

         <oasis:entry colname="col2">Voltage</oasis:entry>

         <oasis:entry colname="col3">Torque</oasis:entry>

         <oasis:entry colname="col4">Speed</oasis:entry>

         <oasis:entry colname="col5" morerows="3">Instability in efficiency</oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry colname="col1"><inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">I</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col2"><inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">V</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.4</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col3"><inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.27</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry colname="col4"><inline-formula><mml:math id="M148" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.01</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry namest="col1" nameend="col2" colsep="1">Electrical power </oasis:entry>

         <oasis:entry namest="col3" nameend="col4" colsep="1">Mechanical power </oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry namest="col1" nameend="col2" colsep="1"><inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">P</mml:mi><mml:mi mathvariant="normal">elec</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.23</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

         <oasis:entry namest="col3" nameend="col4" colsep="1"><inline-formula><mml:math id="M150" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="normal">P</mml:mi><mml:mi mathvariant="normal">mech</mml:mi></mml:msub></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.27</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry namest="col1" nameend="col4" colsep="1">Uncertainty caused by measurement chains </oasis:entry>

         <oasis:entry rowsep="1" colname="col5" morerows="1"><inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub><mml:mo>,</mml:mo><mml:mi mathvariant="normal">ins</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow><mml:mo>*</mml:mo></mml:msubsup><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.041</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
       <oasis:row rowsep="1">

         <oasis:entry namest="col1" nameend="col4" colsep="1"><inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">meas</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.35</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>

       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>

         <oasis:entry namest="col1" nameend="col5" colsep="0">Overall </oasis:entry>

       </oasis:row>
       <oasis:row>

         <oasis:entry namest="col1" nameend="col5" colsep="0"><inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.35</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula>, expanded MU <inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">10</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.70</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) </oasis:entry>

       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e3175">Combining the contributions of measurement chains and the instability yields the overall uncertainty in efficiency shown at the bottom of the table. Obviously, the contribution of instability in this case plays only a negligible role in the uncertainty of the determined efficiency based on a 10-revolution averaged measurement.</p>
</sec>
<sec id="Ch1.S6.SS2">
  <label>6.2</label><title>Operational curve test</title>
      <p id="d2e3186">In the second test, the rotational speed followed a 27-step profile up to the rated speed, while the torque was kept at the nominal level of the TTS, namely 5 MN <inline-formula><mml:math id="M156" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m. Figure <xref ref-type="fig" rid="F8"/> shows the actual test progress. Since only a limited number of revolutions were available on each step, the efficiency shown in Fig. <xref ref-type="fig" rid="F9"/> was calculated with the average of just one revolution, denoted as <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. For each step, calculation was done based on the data from six revolutions, so six efficiency points, each representing the average of a single revolution, are shown. Within each step, the deviation of the six <inline-formula><mml:math id="M158" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> points is clearly shown. The standard deviation <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> for each test step can be calculated using the corresponding six points.</p>

      <fig id="F8" specific-use="star"><label>Figure 8</label><caption><p id="d2e3240">Actual test progress of the operational curve test.</p></caption>
          <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f08.png"/>

        </fig>

      <fig id="F9" specific-use="star"><label>Figure 9</label><caption><p id="d2e3251">Efficiency of one-revolution average for the operational test.</p></caption>
          <graphic xlink:href="https://wes.copernicus.org/articles/10/1625/2025/wes-10-1625-2025-f09.png"/>

        </fig>

      <p id="d2e3261">To obtain the efficiency of each test step, the measurements of all six revolutions were used to determine the six-revolution averaged efficiency <inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>. As pointed out by <xref ref-type="bibr" rid="bib1.bibx7" id="text.12"/>, the measurements of at least six full revolutions should be averaged to achieve a good level of accuracy. The results of <inline-formula><mml:math id="M161" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> for some of the test steps are listed in Table <xref ref-type="table" rid="T5"/>. Since there were not enough revolutions to determine the standard deviation <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> , the value of <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>  is used instead for the calculation of the uncertainty. It is worth pointing out here that the standard deviation of a single revolution's average efficiency is adopted directly instead of in a form similar to Eq. (<xref ref-type="disp-formula" rid="Ch1.E10"/>). This is because six points represent a very limited basis to obtain a reliable calculation of <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> . Using <inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> directly as <inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> serves to yield conservative results in the uncertainty analysis. The overall uncertainty of the determined efficiency is also given in Table <xref ref-type="table" rid="T5"/>. Since the torque remains at 5 MN <inline-formula><mml:math id="M167" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m throughout all the test steps, the uncertainty due to the measurement chains is identical to the value in Table <xref ref-type="table" rid="T4"/> for all the steps: <inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">meas</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.35</mml:mn><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mi mathvariant="italic">%</mml:mi></mml:mrow></mml:math></inline-formula>. This is therefore not listed again in Table <xref ref-type="table" rid="T5"/>. The results show that <inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>,</mml:mo><mml:mi mathvariant="normal">meas</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> plays a dominant role in the uncertainty of the efficiency.</p>

<table-wrap id="T5" specific-use="star"><label>Table 5</label><caption><p id="d2e3429">Determined efficiency and its uncertainty in some of the test steps.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="7">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Step</oasis:entry>
         <oasis:entry colname="col2">7</oasis:entry>
         <oasis:entry colname="col3">11</oasis:entry>
         <oasis:entry colname="col4">15</oasis:entry>
         <oasis:entry colname="col5">19</oasis:entry>
         <oasis:entry colname="col6">23</oasis:entry>
         <oasis:entry colname="col7">27</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M170" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> (normalised)</oasis:entry>
         <oasis:entry colname="col2">0.54</oasis:entry>
         <oasis:entry colname="col3">0.64</oasis:entry>
         <oasis:entry colname="col4">0.73</oasis:entry>
         <oasis:entry colname="col5">0.82</oasis:entry>
         <oasis:entry colname="col6">0.92</oasis:entry>
         <oasis:entry colname="col7">1.00</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M171" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">86.38 %</oasis:entry>
         <oasis:entry colname="col3">87.43 %</oasis:entry>
         <oasis:entry colname="col4">88.12 %</oasis:entry>
         <oasis:entry colname="col5">88.65 %</oasis:entry>
         <oasis:entry colname="col6">89.15 %</oasis:entry>
         <oasis:entry colname="col7">89.84 %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:msub><mml:mi>u</mml:mi><mml:mi mathvariant="normal">ins</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">0.06 %</oasis:entry>
         <oasis:entry colname="col3">0.16 %</oasis:entry>
         <oasis:entry colname="col4">0.09 %</oasis:entry>
         <oasis:entry colname="col5">0.13 %</oasis:entry>
         <oasis:entry colname="col6">0.11 %</oasis:entry>
         <oasis:entry colname="col7">0.09 %</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:msub><mml:mi>U</mml:mi><mml:mrow><mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:mn mathvariant="normal">6</mml:mn></mml:msub></mml:mrow></mml:msub><mml:mo>(</mml:mo><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">0.72 %</oasis:entry>
         <oasis:entry colname="col3">0.76 %</oasis:entry>
         <oasis:entry colname="col4">0.72 %</oasis:entry>
         <oasis:entry colname="col5">0.74 %</oasis:entry>
         <oasis:entry colname="col6">0.74 %</oasis:entry>
         <oasis:entry colname="col7">0.72 %</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
</sec>
<sec id="Ch1.S7">
  <label>7</label><title>Discussion</title>
      <p id="d2e3650">The efficiency determination for both of the tests discussed above achieved an accuracy of approximately 0.7 % uncertainty, thereby breaking the 1 % mark. The largest uncertainty contribution still comes from the torque measurement, despite the use of the best possible torque transducer and calibration machine. To further reduce the uncertainty, the transducer needs to be calibrated to a higher level of torque. PTB is commissioning a new torque calibration machine with a capacity of 5 MN <inline-formula><mml:math id="M174" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m, and this could help achieve better uncertainty.</p>
      <p id="d2e3660">The second largest contribution comes from the voltage measurement. Although in this case it stems from safety regulation requirements and could in particular circumstances be solved by a dedicated reconfiguration of the test bench, it still shows the importance of planning effort and investment in electrical power measurement. In practice, it should not be taken for granted that electrical power can be measured automatically with sufficient accuracy. Because testing time on a nacelle test bench is a limited resource (drivetrain efficiency would very likely be tested together with many other test items), it is not always possible to reconfigure the test layout just for one test. Therefore, it is important to plan the test in advance and take all relevant factors into consideration in order to achieve the best possible electrical measurement accuracy.</p>
      <p id="d2e3663">Rotational speed and electrical current measurements achieved very high levels of accuracy. For these two cases, suitable sensors with careful calibration were instrumented at the right positions on the drivetrain and integrated into well-calibrated measurement chains. All these factors combined produce satisfying results.</p>
      <p id="d2e3666">Owing to a number of discussed reasons, ripples on the measurement and deviations in the determined efficiency are inevitable. To achieve stable efficiency under certain conditions, it is recommended to average at least six full revolutions of measurement. Based on the results of this study, the uncertainty caused by the deviation in efficiency will only represent a minor contributor to the overall MU of efficiency if this recommendation is followed.</p>
      <p id="d2e3670">One limitation of the test layout presented in this paper is that the non-torque loads, such as bending moments and shear forces, could not be applied to the DUT because the 5 MN <inline-formula><mml:math id="M175" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m TTS from PTB is not designed to withstand high levels of non-torque loads. To overcome this limitation, a series of calibration profiles was carried out during the test campaign so that the DyNaLab transducer developed in-house at Fraunhofer IWES could be calibrated. This transducer was placed directly in front of the reference transducer from PTB. The torque calibration of this transducer has been reported by <xref ref-type="bibr" rid="bib1.bibx13" id="text.13"/>. This transducer is designed to withstand and measure loads in all 6 degrees of freedom and will be used for torque measurement in future test campaigns.</p>
</sec>
<sec id="Ch1.S8" sec-type="conclusions">
  <label>8</label><title>Conclusions</title>
      <p id="d2e3691">This paper reported an approach to determine the drivetrain efficiency of a modern multi-megawatt wind turbine drivetrain. Addressing the challenge of measurement accuracy, state-of-the-art sensors, measurement systems and calibration facilities were employed within the framework of the WindEFCY project. The results show that an overall MU of 0.7 % is achievable for an efficiency determination with torque measurement up to 5 MN <inline-formula><mml:math id="M176" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m. As expected, torque measurement contributed the largest share to the overall MU. Surprisingly, the electrical power measurement also played a significant role in the MU. This highlights the fact that although electrical measurements are generally considered to be much more accurate, equal care must be exercised when measuring both electrical and mechanical power. Speed measurement using an inclinometer, however, yielded very good results including a very small MU of 0.01 %. To achieve a stable efficiency result, the measurement of at least six full revolutions was averaged, resulting in nearly negligible contributions to the overall MU.</p>
</sec>

      
      </body>
    <back><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d2e3705">This paper is based on the test campaign of a commercial wind turbine prototype; therefore, the data and the processing code could not be disclosed.</p>
  </notes><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d2e3711">HZ conceptualised the paper, carried out the data analysis and wrote the major part of the paper. PW and ZS were responsible for torque and speed measurement, as well as the corresponding text in this paper. CM and AD were responsible for electrical power measurement, as well as the corresponding text in this paper. AD also carried out the comprehensive calibration of the HILO voltage dividers. MH and KE coordinated the project and test execution. BT took part in the sensor instrumentation.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e3717">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e3724">Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.</p>
  </notes><notes notes-type="sistatement"><title>Special issue statement</title>

      <p id="d2e3730">This article is part of the special issue “`Electro-mechanical interactions in wind turbines”. It is not associated with a conference.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e3736">The project 19ENG08 WindEFCY has received funding from the EMPIR programme co-financed by the participating states from the European Union’s Horizon 2020 research and innovation programme. The input of all the project partners is gratefully acknowledged.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d2e3741">This research has been supported by the European Metrology Programme for Innovation and Research (grant no. 19ENG08).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e3747">This paper was edited by Yi Guo and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Foyer et al.(2019)Foyer, Kock, and Weidinger</label><mixed-citation>Foyer, G., Kock, S., and Weidinger, P.: Influences on torque measurement in nacelle test benches and their effect on the measurement uncertainty and consequences of a torque calibration, ACTA IMEKO, 8, 59, <ext-link xlink:href="https://doi.org/10.21014/acta_imeko.v8i3.658" ext-link-type="DOI">10.21014/acta_imeko.v8i3.658</ext-link>, 2019.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>JCGM(2008)</label><mixed-citation>JCGM: Evaluation of measurement data – Guide to the Expression of Uncertainty in Measurement (GUM), Standard, Joint Committee for Guides in Metrology JCGM, <uri>https://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf</uri> (last access: 6 August 2025), 2008.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>JCGM(2012)</label><mixed-citation>JCGM: International vocabulary of metrology – Basic and general concepts and associated terms (VIM), 3rd edn., 2008 version with minor corrections, Joint Commitee for Guides in Metorology, JCGM 200, <uri>https://www.bipm.org/documents/20126/2071204/JCGM_200_2012.pdf</uri> (last access: 6 August 2025), 2012.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Mester(2021)</label><mixed-citation>Mester, C.: Sampling Primary Power Standard from DC up to 9 kHz Using Commercial Off-The-Shelf Components, Energies, 14, 2203, <ext-link xlink:href="https://doi.org/10.3390/en14082203" ext-link-type="DOI">10.3390/en14082203</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Pagitsch et al.(2016)Pagitsch, Jacobs, Schelenz, Bosse, Liewen, Reisch, and Deicke</label><mixed-citation>Pagitsch, M., Jacobs, G., Schelenz, R., Bosse, D., Liewen, C., Reisch, S., and Deicke, M.: Feasibility of large-scale calorimetric efficiency measurement for wind turbine generator drivetrains, J. Phys. Conf. Ser., 753, 072011, <ext-link xlink:href="https://doi.org/10.1088/1742-6596/753/7/072011" ext-link-type="DOI">10.1088/1742-6596/753/7/072011</ext-link>, 2016. </mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Song et al.(2022)Song, Weidinger, Zhang, Heller, Oliveira, and Kumme</label><mixed-citation>Song, Z., Weidinger, P., Zhang, H., Heller, M., Oliveira, R., and Kumme, R.: Metrological characterisation of rotational speed measurement using an inclinometer in a nacelle test bench, in: 21. ITG/GMA Fachtagung Sensoren und Messsysteme,  Nuremberg, Germany, 10–11 May 2022, <uri>https://ieeexplore.ieee.org/abstract/document/9861893</uri> (last access: 6 August 2025), 2022.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Song et al.(2023)Song, Weidinger, Zweiffel, Dubowik, Mester, Yogal, and Oliveira</label><mixed-citation>Song, Z., Weidinger, P., Zweiffel, M., Dubowik, A., Mester, C., Yogal, N., and Oliveira, R.: Traceable efficiency determination of a 2.75 MW nacelle on a test bench, Forsch. Ingenieurwes., 87, 259–273, <ext-link xlink:href="https://doi.org/10.1007/s10010-023-00650-1" ext-link-type="DOI">10.1007/s10010-023-00650-1</ext-link>, 2023.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Weidinger et al.(2017)Weidinger, Schlegel, Foyer, and Kumme</label><mixed-citation>Weidinger, P., Schlegel, C., Foyer, G., and Kumme, R.: Characterisation of a 5 MN <inline-formula><mml:math id="M177" display="inline"><mml:mo>⋅</mml:mo></mml:math></inline-formula> m torque transducer by combining traditional calibration and finite element method simulations, in: AMA Conferences, Nuremberg, Germany, 30 May–1 June 2017, <ext-link xlink:href="https://doi.org/10.5162/sensor2017/D6.2" ext-link-type="DOI">10.5162/sensor2017/D6.2</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Weidinger et al.(2021)Weidinger, Dubowik, Lehrmann, Yogal, Kumme, Zweiffel, Eich, Mester, and Zhang</label><mixed-citation>Weidinger, P., Dubowik, A., Lehrmann, C., Yogal, N., Kumme, R., Zweiffel, M., Eich, N., Mester, C., and Zhang, H.: Need for a traceable efficiency determination method of nacelles performed on test benches, Measurement: Sensors, 18, 100159, <ext-link xlink:href="https://doi.org/10.1016/j.measen.2021.100159" ext-link-type="DOI">10.1016/j.measen.2021.100159</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Weidinger et al.(2023a)Weidinger, Song, Oliveira, Vavrečka, Fidelus, Kananen, Heller, and Zhang</label><mixed-citation>Weidinger, P., Song, Z., de Oliveira, R. S., Vavrečka, L., Fidelus, J., Kananen, T., Heller, M., and Zhang, H.: Report describing the calibration of the 5 MN m torque transfer standard partially up to 1.1 MN m with an uncertainty <inline-formula><mml:math id="M178" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.1</mml:mn></mml:mrow></mml:math></inline-formula> % and in the full range up to 5 MN m with an uncertainty <inline-formula><mml:math id="M179" display="inline"><mml:mrow><mml:mo>&lt;</mml:mo><mml:mn mathvariant="normal">0.5</mml:mn></mml:mrow></mml:math></inline-formula> % with synchronised measurements of rotational speed up to 20 rpm on the low-speed shaft respectively torque measurements up to 100 kN m with synchronised measurements of rotational speed up to 1600 rpm on the high-speed shaft, <ext-link xlink:href="https://doi.org/10.5281/zenodo.8112428" ext-link-type="DOI">10.5281/zenodo.8112428</ext-link>, 2023a.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Weidinger et al.(2023b)</label><mixed-citation>Weidinger, P., Song, Z., Oliveira, R. S., Sander, J., Vavrečka, L., Fidelus, J., Heller, M., Zhang, H., Zweiffel, M., and Kananen, T.: Good Practice Guide on the calibration procedure for traceable mechanical power measurement based on synchronised torque and rotational speed measurement, <ext-link xlink:href="https://doi.org/10.5281/zenodo.10081870" ext-link-type="DOI">10.5281/zenodo.10081870</ext-link>, 2023b.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Zhang and Neshati(2018)</label><mixed-citation>Zhang, H. and Neshati, M.: An effective method of determining the drive-train effciency of wind turbines with high accuracy, J. Phys. Conf. Ser., 1037, 052013, <ext-link xlink:href="https://doi.org/10.1088/1742-6596/1037/5/052013" ext-link-type="DOI">10.1088/1742-6596/1037/5/052013</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Zhang et al.(2023)Zhang, Pieper, and Heller</label><mixed-citation>Zhang, H., Pieper, S., and Heller, M.: Direct measurement of input loads for the wind turbine drivetrain under test on a nacelle test bench, Forsch. Ingenieurwes., 87, 93–105, <ext-link xlink:href="https://doi.org/10.1007/s10010-023-00628-z" ext-link-type="DOI">10.1007/s10010-023-00628-z</ext-link>, 2023.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>State-of-the-art efficiency determination of a wind turbine drivetrain on a nacelle test bench</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Foyer et al.(2019)Foyer, Kock, and
Weidinger</label><mixed-citation>
      
Foyer, G., Kock, S., and Weidinger, P.: Influences on torque measurement in
nacelle test benches and their effect on the measurement uncertainty and
consequences of a torque calibration, ACTA IMEKO, 8, 59,
<a href="https://doi.org/10.21014/acta_imeko.v8i3.658" target="_blank">https://doi.org/10.21014/acta_imeko.v8i3.658</a>, 2019.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>JCGM(2008)</label><mixed-citation>
      
JCGM: Evaluation of measurement data – Guide to the Expression of Uncertainty
in Measurement (GUM), Standard, Joint Committee for Guides in Metrology JCGM, <a href="https://www.bipm.org/utils/common/documents/jcgm/JCGM_100_2008_E.pdf" target="_blank"/> (last access: 6 August 2025),
2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>JCGM(2012)</label><mixed-citation>
      
JCGM: International vocabulary of metrology – Basic and general concepts and associated terms (VIM), 3rd edn., 2008 version with minor corrections, Joint Commitee for Guides in Metorology, JCGM 200, <a href="https://www.bipm.org/documents/20126/2071204/JCGM_200_2012.pdf" target="_blank"/> (last access: 6 August 2025), 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Mester(2021)</label><mixed-citation>
      
Mester, C.: Sampling Primary Power Standard from DC up to 9&thinsp;kHz Using
Commercial Off-The-Shelf Components, Energies, 14, 2203, <a href="https://doi.org/10.3390/en14082203" target="_blank">https://doi.org/10.3390/en14082203</a>,
2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Pagitsch et al.(2016)Pagitsch, Jacobs, Schelenz, Bosse, Liewen,
Reisch, and Deicke</label><mixed-citation>
      
Pagitsch, M., Jacobs, G., Schelenz, R., Bosse, D., Liewen, C., Reisch, S., and
Deicke, M.: Feasibility of large-scale calorimetric efficiency measurement
for wind turbine generator drivetrains, J. Phys. Conf.
Ser., 753, 072011, <a href="https://doi.org/10.1088/1742-6596/753/7/072011" target="_blank">https://doi.org/10.1088/1742-6596/753/7/072011</a>, 2016.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Song et al.(2022)Song, Weidinger, Zhang, Heller, Oliveira, and
Kumme</label><mixed-citation>
      
Song, Z., Weidinger, P., Zhang, H., Heller, M., Oliveira, R., and Kumme, R.:
Metrological characterisation of rotational speed measurement using an
inclinometer in a nacelle test bench, in: 21. ITG/GMA Fachtagung Sensoren und
Messsysteme,  Nuremberg, Germany, 10–11 May 2022, <a href="https://ieeexplore.ieee.org/abstract/document/9861893" target="_blank"/> (last access: 6 August 2025), 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Song et al.(2023)Song, Weidinger, Zweiffel, Dubowik, Mester, Yogal,
and Oliveira</label><mixed-citation>
      
Song, Z., Weidinger, P., Zweiffel, M., Dubowik, A., Mester, C., Yogal, N., and
Oliveira, R.: Traceable efficiency determination of a 2.75&thinsp;MW nacelle on a
test bench, Forsch. Ingenieurwes., 87, 259–273,
<a href="https://doi.org/10.1007/s10010-023-00650-1" target="_blank">https://doi.org/10.1007/s10010-023-00650-1</a>, 2023.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Weidinger et al.(2017)Weidinger, Schlegel, Foyer, and
Kumme</label><mixed-citation>
      
Weidinger, P., Schlegel, C., Foyer, G., and Kumme, R.: Characterisation of a 5
MN&thinsp; ⋅ &thinsp;m torque transducer by combining traditional calibration
and finite element method simulations, in: AMA Conferences, Nuremberg, Germany, 30 May–1 June 2017,
<a href="https://doi.org/10.5162/sensor2017/D6.2" target="_blank">https://doi.org/10.5162/sensor2017/D6.2</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Weidinger et al.(2021)Weidinger, Dubowik, Lehrmann, Yogal, Kumme,
Zweiffel, Eich, Mester, and Zhang</label><mixed-citation>
      
Weidinger, P., Dubowik, A., Lehrmann, C., Yogal, N., Kumme, R., Zweiffel, M.,
Eich, N., Mester, C., and Zhang, H.: Need for a traceable efficiency
determination method of nacelles performed on test benches, Measurement:
Sensors, 18, 100159, <a href="https://doi.org/10.1016/j.measen.2021.100159" target="_blank">https://doi.org/10.1016/j.measen.2021.100159</a>,
2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Weidinger et al.(2023a)Weidinger, Song, Oliveira, Vavrečka, Fidelus,
Kananen, Heller, and Zhang</label><mixed-citation>
      
Weidinger, P., Song, Z., de Oliveira, R. S., Vavrečka, L., Fidelus, J.,
Kananen, T., Heller, M., and Zhang, H.: Report describing the calibration of the 5 MN m torque transfer standard partially up to 1.1&thinsp;MN&thinsp;m with an uncertainty  &lt; 0.1&thinsp;% and in the full range up to 5&thinsp;MN&thinsp;m with an uncertainty  &lt; 0.5&thinsp;% with synchronised measurements of rotational speed up to 20&thinsp;rpm on the low-speed shaft respectively torque measurements up to 100&thinsp;kN&thinsp;m with synchronised measurements of rotational speed up to 1600&thinsp;rpm on the high-speed shaft,
<a href="https://doi.org/10.5281/zenodo.8112428" target="_blank">https://doi.org/10.5281/zenodo.8112428</a>, 2023a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Weidinger et al.(2023b)</label><mixed-citation>
      
Weidinger, P., Song, Z., Oliveira, R. S., Sander, J., Vavrečka, L., Fidelus, J., Heller, M., Zhang, H., Zweiffel, M., and Kananen, T.: Good Practice Guide on the calibration procedure for traceable mechanical power measurement based on synchronised torque and rotational speed measurement, <a href="https://doi.org/10.5281/zenodo.10081870" target="_blank">https://doi.org/10.5281/zenodo.10081870</a>, 2023b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Zhang and Neshati(2018)</label><mixed-citation>
      
Zhang, H. and Neshati, M.: An effective method of determining the drive-train
effciency of wind turbines with high accuracy, J. Phys. Conf.
Ser., 1037, 052013, <a href="https://doi.org/10.1088/1742-6596/1037/5/052013" target="_blank">https://doi.org/10.1088/1742-6596/1037/5/052013</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Zhang et al.(2023)Zhang, Pieper, and Heller</label><mixed-citation>
      
Zhang, H., Pieper, S., and Heller, M.: Direct measurement of input loads for
the wind turbine drivetrain under test on a nacelle test bench, Forsch.
Ingenieurwes., 87, 93–105, <a href="https://doi.org/10.1007/s10010-023-00628-z" target="_blank">https://doi.org/10.1007/s10010-023-00628-z</a>, 2023.

    </mixed-citation></ref-html>--></article>