# By Lars Einar S. Stieng
# Fatigue estimates for design MD10.
# Columns are number of samples used (1), estimate at tower bottom (2), tower top (3) and mudline (4).
   7.0000000e+00   6.7676092e-04   4.8870359e-03  -8.3859266e-02
   1.5000000e+01  -5.1137624e-04  -1.2122958e-02  -5.6750688e-02
   1.9000000e+01  -5.2984026e-03  -2.0525221e-02  -4.2370726e-02
   2.7000000e+01  -2.3206957e-03  -1.3572672e-02  -2.9324356e-02
   3.3000000e+01  -3.1089097e-03  -1.0928857e-02  -2.5650838e-02
   3.9000000e+01  -8.6498823e-03  -9.3065670e-03  -2.9122681e-02
   4.7000000e+01  -9.2508887e-03  -7.1442154e-03  -2.6186319e-02
   5.3000000e+01  -6.5851388e-03  -7.1743570e-03  -1.8894605e-02
   6.4000000e+01  -8.1477964e-03  -7.8709555e-03  -1.9019027e-02
   6.9000000e+01  -9.7468750e-03  -3.5910089e-03  -2.0355610e-02
   7.5000000e+01  -9.6140687e-03  -3.6866195e-03  -2.0418326e-02
   7.9000000e+01  -7.5385560e-03  -4.0842458e-03  -1.8986361e-02
   8.3000000e+01  -8.9352944e-03  -4.5030466e-03  -2.0822022e-02
   8.7000000e+01  -8.5869830e-03  -4.0378935e-03  -1.8185170e-02
   9.1000000e+01  -7.7051664e-03  -4.2509962e-03  -1.7455087e-02
   9.8000000e+01  -8.4619439e-03  -4.4321484e-03  -1.7482433e-02
   1.0200000e+02  -7.2779519e-03  -4.2917534e-03  -1.6718090e-02
   1.0700000e+02  -7.9871076e-03  -2.9921147e-03  -1.7464818e-02
   1.1800000e+02  -6.3555578e-03  -2.5883694e-03  -1.4281714e-02
   1.2200000e+02  -5.9968982e-03  -1.8933114e-03  -1.3405713e-02
   1.2900000e+02  -4.7180787e-03  -1.9729529e-03  -1.2470411e-02
   1.3400000e+02  -5.0727235e-03  -1.2603740e-03  -1.2953920e-02
   1.3700000e+02  -4.9810845e-03  -1.0531740e-03  -1.2221429e-02
   1.4200000e+02  -4.7219900e-03  -1.2738545e-03  -1.2486344e-02
   1.5000000e+02  -4.5954000e-03  -8.9660209e-04  -1.2651262e-02
   1.5800000e+02  -3.8193149e-03  -8.3725763e-04  -1.1605362e-02
   1.6400000e+02  -3.6836518e-03  -7.7721598e-04  -1.0514855e-02
   1.7100000e+02  -3.6898683e-03  -5.2949694e-04  -1.0257648e-02
   1.7700000e+02  -4.0054352e-03  -3.7076131e-04  -1.0229991e-02
   1.8100000e+02  -3.9347471e-03  -3.6963095e-04  -9.8447757e-03