# By Lars Einar S. Stieng
# Fatigue estimates for design MD5.
# Columns are number of samples used (1), estimate at tower bottom (2), tower top (3) and mudline (4).
   1.8000000e+01   6.7157222e-03  -1.1370343e-02  -1.5864923e-02
   3.6000000e+01   1.3758267e-03  -6.0392379e-03  -1.2043725e-02
   7.4000000e+01  -3.4849282e-03  -2.7570445e-03  -1.0601392e-02
   9.1000000e+01  -2.2376493e-03  -2.3138926e-03  -7.7287265e-03
   1.2200000e+02  -1.9249481e-03  -8.8630192e-04  -5.6857256e-03
   1.8300000e+02  -1.6583053e-03  -4.6351801e-04  -4.2844508e-03
   3.6500000e+02  -9.0389787e-04  -2.2601197e-04  -1.7980814e-03
   7.3000000e+02  -2.9550981e-04  -6.1019247e-05  -6.1300567e-04
   9.1100000e+02  -2.3860755e-04  -1.4461528e-05  -4.4949529e-04
   1.2170000e+03  -1.2562915e-04   1.5782547e-05  -2.4406280e-04
   1.8260000e+03  -1.0221329e-05   3.3161162e-06  -4.6478363e-05