Articles | Volume 11, issue 5
https://doi.org/10.5194/wes-11-1607-2026
https://doi.org/10.5194/wes-11-1607-2026
Research article
 | 
08 May 2026
Research article |  | 08 May 2026

Scaled testing of maximum-reserve active power control

Simone Tamaro, Davide Bortolin, Filippo Campagnolo, Franz V. Mühle, and Carlo L. Bottasso

Related authors

A robust active power control algorithm to maximize wind farm power tracking margins in waked conditions
Simone Tamaro, Filippo Campagnolo, and Carlo L. Bottasso
Wind Energ. Sci., 10, 2705–2728, https://doi.org/10.5194/wes-10-2705-2025,https://doi.org/10.5194/wes-10-2705-2025, 2025
Short summary
On the power and control of a misaligned rotor – beyond the cosine law
Simone Tamaro, Filippo Campagnolo, and Carlo L. Bottasso
Wind Energ. Sci., 9, 1547–1575, https://doi.org/10.5194/wes-9-1547-2024,https://doi.org/10.5194/wes-9-1547-2024, 2024
Short summary
Vertical wake deflection for floating wind turbines by differential ballast control
Emmanouil M. Nanos, Carlo L. Bottasso, Simone Tamaro, Dimitris I. Manolas, and Vasilis A. Riziotis
Wind Energ. Sci., 7, 1641–1660, https://doi.org/10.5194/wes-7-1641-2022,https://doi.org/10.5194/wes-7-1641-2022, 2022
Short summary

Cited articles

Aho, J., Buckspan, A., Laks, J., Fleming, P., Jeong, Y., Dunne, F., Churchfield, M., Pao, L., and Johnson, K.: A tutorial of wind turbine control for supporting grid frequency through active power control, in: 2012 American Control Conference (ACC), https://doi.org/10.1109/ACC.2012.6315180, 3120–3131, 2012. a, b, c, d
Bachmann electronic GmbH: System Overview, Bachmann electronic GmbH, Feldkirch, 2017. a, b
Bastankhah, M. and Porté-Agel, F.: A new analytical model for wind-turbine wakes, Renew. Energ., 70, 116–123, https://doi.org/10.1016/j.renene.2014.01.002, 2014. a, b, c
Boersma, S., Rostampour, V., Doekemeijer, B., van Geest, W., and van Wingerden, J.-W.: A constrained model predictive wind farm controller providing active power control: an LES study, J. Phys. Conf. Ser., 1037, 032023, https://doi.org/10.1088/1742-6596/1037/3/032023, 2018. a
Bortolotti, P., Tarres, H. C., Dykes, K. L., Merz, K., Sethuraman, L., Verelst, D., and Zahle, F.: IEA Wind TCP Task 37: Systems Engineering in Wind Energy – WP2.1 Reference Wind Turbines, Tech. rep., National Renewable Energy Lab. (NREL), https://doi.org/10.2172/1529216, 2019. a
Download
Short summary
This work presents the scaled experimental validation of an active power control (APC) algorithm that improves wind farm power-tracking accuracy during turbulent wind lulls. Tests in a large low-blockage wind tunnel, including dynamic wind-direction changes, show that the method outperforms three reference APC strategies, especially under high power demand, while keeping structural fatigue low.
Share
Altmetrics
Final-revised paper
Preprint